This work presents a methodology for detection of QRS complexes which is an adaptation of Pan-Tompkins algorithm. This method includes band bass filtration, derivative, squaring, moving window integration, thresholding, false peak cancellation and detection the predominant peak of QRS complex. This method doing well in the presence of noise and simple ectopic beats but still affected by multifocal ectopic beats. The method was tested on the MIT-BIH Arrhythmia database and achieves accuracy 99.68%.
Published in | International Journal of Medical Imaging (Volume 2, Issue 6) |
DOI | 10.11648/j.ijmi.20140206.12 |
Page(s) | 133-137 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2014. Published by Science Publishing Group |
ECG, QRS, Ectopic beat, Butterworth Filter
[1] | Chen W. Mo Z. Guo W. "Detection of QRS Complexes Using Wavelet Transforms and Golden Section Search" , Biomedical Engineering , Issue 4 , Page 748-751,2009 |
[2] | Sumathi S., Sanavullah M. Y. , "Comparative Study of QRS Complex Detection in ECG Based on Discrete Wavelet Transform" , International Journal of Recent Trends in Engineering, Vol 2, No. 5, November 2009 |
[3] | Pan J., Tompkins W. , "A Real-Time QRS Detection Algorithm" , IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. BME-32, NO. 3, page 230-236,1985 |
[4] | Clifford G.D. , Azuaje F. , McSharry P. E. , Advanced Methods and Tools for ECG Data Analysis, ,ARTECH HOUSE.2006. |
[5] | Van J.., Van W., Herrmann E. , ECG Baseline Wander Reduction Using Linear Phase Filters, COMPUTERS AND BIOMEDICAL RESEARCH, 19, 1986, pp.417-427, 1986. |
[6] | Tompkins W.J., "Biomedical Digital Signal Processing" Prentice Hall (Englewood Cliffs, N.J.), 2002. |
[7] | Yeh Y. , Wang W. ,"QRS complexes detection for ECG signal: The Difference Operation Method ", Computer Methods and Programs in Biomedicine, Vol 91, Issue 3 , page 245-254, 2008 |
[8] | Arthur C. Guyton, M.D., John E. Hall, Ph.D. , " TEXTBOOK of Medical Physiology" , eleventh edition, Elsevier, 2006. |
APA Style
Ahmed Saad Al-Ghabban, Abbas Fathil Al-Hashimi, Ziad Tariq Al-Dahan. (2014). Predominant Peak Detection of QRS Complexes. International Journal of Medical Imaging, 2(6), 133-137. https://doi.org/10.11648/j.ijmi.20140206.12
ACS Style
Ahmed Saad Al-Ghabban; Abbas Fathil Al-Hashimi; Ziad Tariq Al-Dahan. Predominant Peak Detection of QRS Complexes. Int. J. Med. Imaging 2014, 2(6), 133-137. doi: 10.11648/j.ijmi.20140206.12
AMA Style
Ahmed Saad Al-Ghabban, Abbas Fathil Al-Hashimi, Ziad Tariq Al-Dahan. Predominant Peak Detection of QRS Complexes. Int J Med Imaging. 2014;2(6):133-137. doi: 10.11648/j.ijmi.20140206.12
@article{10.11648/j.ijmi.20140206.12, author = {Ahmed Saad Al-Ghabban and Abbas Fathil Al-Hashimi and Ziad Tariq Al-Dahan}, title = {Predominant Peak Detection of QRS Complexes}, journal = {International Journal of Medical Imaging}, volume = {2}, number = {6}, pages = {133-137}, doi = {10.11648/j.ijmi.20140206.12}, url = {https://doi.org/10.11648/j.ijmi.20140206.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijmi.20140206.12}, abstract = {This work presents a methodology for detection of QRS complexes which is an adaptation of Pan-Tompkins algorithm. This method includes band bass filtration, derivative, squaring, moving window integration, thresholding, false peak cancellation and detection the predominant peak of QRS complex. This method doing well in the presence of noise and simple ectopic beats but still affected by multifocal ectopic beats. The method was tested on the MIT-BIH Arrhythmia database and achieves accuracy 99.68%.}, year = {2014} }
TY - JOUR T1 - Predominant Peak Detection of QRS Complexes AU - Ahmed Saad Al-Ghabban AU - Abbas Fathil Al-Hashimi AU - Ziad Tariq Al-Dahan Y1 - 2014/11/18 PY - 2014 N1 - https://doi.org/10.11648/j.ijmi.20140206.12 DO - 10.11648/j.ijmi.20140206.12 T2 - International Journal of Medical Imaging JF - International Journal of Medical Imaging JO - International Journal of Medical Imaging SP - 133 EP - 137 PB - Science Publishing Group SN - 2330-832X UR - https://doi.org/10.11648/j.ijmi.20140206.12 AB - This work presents a methodology for detection of QRS complexes which is an adaptation of Pan-Tompkins algorithm. This method includes band bass filtration, derivative, squaring, moving window integration, thresholding, false peak cancellation and detection the predominant peak of QRS complex. This method doing well in the presence of noise and simple ectopic beats but still affected by multifocal ectopic beats. The method was tested on the MIT-BIH Arrhythmia database and achieves accuracy 99.68%. VL - 2 IS - 6 ER -